Xpert Self-Expanding Stent System (International)

THE ONE AND ONLY
The world`s first 4F compatible self-expanding stent system, specifically designed for small vessels with focus on hemodynamics.
Innovation and technology have resulted in a new generation of the Xpert small vessel stent system, now enabling to treat peripheral vessels from diameter 2 mm up to 7 mm.
Each stent diameter was specifically developed to guarantee a Nitinol/vessel
wall coverage of maximum 20%.
Features and Benefits
Designed for small vessels

The Xpert has a homogeneous and diameter independent constant arterial surface coverage (each stent diameter is specifically designed). The wall coverage is reduced compared to other NiTi stents.
Optimized hemodynamics
The relative wall coverage can be compared to a standard stent in a larger vessel. The low strut profile also contributes to optimizing the vessel lumen and minimizing the flow disturbance. This design assures minimal reduction of vessel lumen when placed in a small vessel.
Strut profile designed for |
Strut profile designed for large |
Specifically designed Xpert |
Design Details
| Stent Ø (mm) | Design | Sheath compatibility (F) | Strut Thickness (mm) | Wall Thickness (mm) |
| 3 | 9 cells | 4 | 0.09 | 0.11 |
| 4 | 9 cells | 4 | 0.09 | 0.14 |
| 5,6 | 9 cells | 4 | 0.11 | 0.16 |
| 6x60 | 9 cells | 5 | 0.11 | 0.16 |
| 8 | 12 cells | 5 | 0.14 | 0.16 |
Radial force

Higher radial force compared to other 0.018” guidewire systems. No compromise
in radial force compared to 0.035” guidewire systems.
Conformability

In tortuous anatomy, a good wall apposition ensures, that vessel lumen is not
reduced and hemodynamics is maintained.
Technical Information
| Stent material: | Nitinol |
| Recommended guidewire: | 0.018 |
Ordering Information
Recommended Guidewire: 0.018”
MRI Safe
| Usable Shaft Length | Reference Vessel Duct, Ø | Unconstrained Stent, Ø | Stent Length | Sheath Compatibility | |
| 90 cm Art. No. |
135 cm Art. No |
(mm) | (mm) | (mm) | F |
| EX8S2003 | EX8L2003 | 2-2,5 | 3 | 20 | 4 |
| EX8S3003 | EX8L3003 | 2-2,5 | 3 | 30 | 4 |
| EX8S4003 | EX8L4003 | 2-2,5 | 3 | 40 | 4 |
| EX8S2004 | EX8L2004 | 2,5-3 | 4 | 20 | 4 |
| EX8S3004 | EX8L3004 | 2,5-3 | 4 | 30 | 4 |
| EX8S4004 | EX8L4004 | 2,5-3 | 4 | 40 | 4 |
| EX8S6004 | EX8L6004 | 2,5-3 | 4 | 60 | 4 |
| Usable Shaft Length | Reference Vessel Duct, Ø | Unconstrained Stent, Ø | Stent Length | Sheath Compatibility | |
| 80 cm Art. No. |
120 cm Art. No |
(mm) | (mm) | (mm) | F |
| EX8S2005 | EX8L2005 | 3-4 | 5 | 20 | 4 |
| EX8S3005 | EX8L3005 | 3-4 | 5 | 30 | 4 |
| EX8S4005 | EX8L4005 | 3-4 | 5 | 40 | 4 |
| EX8S6005 | EX8L6005 | 3-4 | 5 | 60 | 4 |
| EX8S2006 | EX8L2006 | 4-5 | 6 | 20 | 4 |
| EX8S3006 | EX8L3006 | 4-5 | 6 | 30 | 4 |
| EX8S4006 | EX8L4006 | 4-5 | 6 | 40 | 4 |
| EX8S6006 | EX8L6006 | 4-5 | 6 | 60 | 5 |
| EX8S3008 | EX8L3008 | 5-7 | 8 | 30 | 5 |
| EX8S4008 | EX8L4008 | 5-7 | 8 | 40 | 5 |
| EX8S6008 | EX8L6008 | 5-7 | 8 | 60 | 5 |
| * The implanted stent is MRI safe and does not interfere with, nor is affected by the operation of an MRI device | |||||