Coronary Dilatation Catheters

JOCATH MERCURY PTCA Catheter

Indications & Important Safety Information ››

 

 

Overview

Abbott Vascular Devices brings you a PTCA balloon catheter for even the most complex procedures.

The unique shaft construction of Mercury ensures full control of the catheter from hub to tip - proximally providing the push where performance is needed, while distally displaying the flexibility and low profile for excellent lesion crossability.*

Mercury has a versatile design making it suitable for a wide range of applications. Its unique controlled compliance characteristics will make it your first choice every time.

mercury

* Tests performed by and data on file at Abbott Vascular.

Features
Balloon Material:
bm2
Balloon Compliance:
Semi-compliant
Shaft Diameter: 2.0F proximal 2.7F distal
Shaft Length: 140-145 cm
Lesion Entry Profile:
0.017"
Nominal Pressure:
8 bar
Rated Burst Pressure:
16 bar
Average Burst Pressure:
22 bar
Coating: HYDREX Coating System
Min. Guiding Catheter:
5F (0.058")

 

 

 

JOCATH MERCURY Compliance Charts*

Pressure (bar) Balloon Diameter (mm)
1.50 2.00 2.25
2.50
2.75
3.00
3.25
3.50
4.00
4 1.43 1.91 2.15 2.39 2.63 2.87 3.11 3.34 3.82
5 1.45 1.93 2.18 2.42 2.66 2.90 3.14 3.38 3.86
6 1.47 1.96 2.20 2.45 2.69 2.93 3.18 3.42 3.91
7 1.48 1.98 2.23 2.47 2.72 2.97 3.22 3.46 3.95
8 1.50 2.00 2.25 2.50 2.75 3.00 3.25 3.50 4.00
9 1.52 2.03 2.28 2.53 2.78 3.04 3.29 3.54 4.04
10 1.53 2.05 2.31 2.56 2.81 3.07 3.33 3.58 4.09
11 1.55 2.07 2.33 2.59 2.84 3.10 3.36 3.62 4.13
12 1.57 2.10 2.36 2.61 2.87 3.14 3.40 3.66 4.18
13 1.59 2.12 2.38 2.64 2.91 3.17 3.44 3.70 4.22
14 1.60 2.14 2.41 2.67 2.94 3.21 3.48 3.74 4.27
15 1.62 2.16 2.44 2.70 2.97 3.24 3.51 3.78 4.31
16 1.64 2.19 2.46 2.73 3.00 3.27 3.55 3.82 4.36
17 1.65 2.21 2.49 2.75 3.03 3.31 3.59 3.86 4.40
18 1.67 2.23 2.51 2.78 3.06 3.34 3.62 3.90 4.45
19 1.69 2.26 2.54 2.81 3.09 3.38 3.66 3.94 4.49
20 1.70 2.28 2.57 2.84 3.12 3.41 3.70 3.98 4.54

† Nominal pressure
‡ Rated burst pressure
* Tests performed by and data on file at Abbott Vascular.

Ordering Information
Order NumberBalloon LengthBalloon DiameterNo. of Radiopaque Markers
M3111511 mm1.50 mm1
M3112011 mm2.00 mm2
M3112511 mm2.50 mm2
M3113011 mm3.00 mm2
M3113511 mm3.50 mm2
M3114011 mm4.00 mm2
M3141514 mm1.50 mm1
M3142014 mm2.00 mm2
M3142514 mm2.50 mm2
M3143014 mm3.00 mm2
M3143514 mm3.50 mm2
M3144014 mm4.00 mm2
M3201520 mm1.50 mm1
M3202020 mm2.00 mm2
M3202220 mm2.25 mm2
M3202520 mm2.50 mm2
M3202720 mm2.75 mm2
M3203020 mm3.00 mm2
M3203220 mm3.25 mm2
M3203520 mm3.50 mm2
M3204020 mm4.00 mm2