Peripheral & Biliary Self-Expanding Stent Systems

Xpert Self-Expanding Stent System

Indications & Important Safety Information ››

 

 

Overview

xpertThe One and Only

The world's first 4F compatible self-expanding stent system, specifically designed for small vessels with focus on hemodynamics.

Innovation and technology have resulted in a new generation of the Xpert small vessel stent system, now enabling to treat peripheral vessels from diameter 2 mm up to 7 mm.

Each stent diameter was specifically developed to guarantee a Nitinol/vessel wall coverage of maximum 20%.

Features
Designed for small vessels
xpert1
The Xpert has a homogeneous and diameter independent constant arterial surface coverage (each stent diameter is specifically designed). The wall coverage is reduced compared to other NiTi stents.
Optimized hemodynamics
The relative wall coverage can be compared to a standard stent in a larger vessel. The low strut profile also contributes to optimizing the vessel lumen and minimizing the flow disturbance. This design assures minimal reduction of vessel lumen when placed in a small vessel.
lumen 1
Strut profile designed for large vessels in a large vessel
lumen 2
Strut profile designed for large vessels in a small vessel
lumen 3
Specifically designed Xpert strut profile in a small vessel
Radial Force
graph
Higher radial force compared to other 0.018” guidewire systems. No compromise in radial force compared to 0.035” guidewire systems.
Conformability
conform1conform2
In tortuous anatomy, a good wall apposition ensures, that vessel lumen is not reduced and hemodynamics is maintained.

 

Specifications
Stent material: Nitinol
Recommended guidewire: 0.018
Ordering Information

Recommended Guidewire: 0.018"

MRI Safe

Usable Shaft LengthReference Vessel Duct, Ø (mm)Unconstrained Stent, Ø (mm)Stent Length (mm)Sheath Compatibility
F
90 cm
Art. No.
135 cm
Art. No.
EX8S2003EX8L20032-2.53204
EX8S3003EX8L30032-2.53304
EX8S4003EX8L40032-2.53404
EX8S2004EX8L20042.5-3.54204
EX8S3004EX8L30042.5-3.54304
EX8S4004EX8L40042.5-3.54404
EX8S6004EX8L60042.5-3.54604
Usable Shaft LengthReference Vessel Duct, Ø (mm)Unconstrained Stent, Ø (mm)Stent Length (mm)Sheath Compatibility
F
80 cm
Art. No.
120 cm
Art. No.
EX8S2005EX8L20053-45204
EX8S3005EX8L30053-45304
EX8S4005EX8L40053-45404
EX8S6005EX8L60053-45604
EX8S2006EX8L20064-56204
EX8S3006EX8L30064-56304
EX8S4006EX8L40064-56404
EX8S6006EX8L60064-56605
EX8S3008EX8L30085-78305
EX8S4008EX8L4008
5-78405
EX8S6008EX8L60085-78605

* The implanted stent is MRI safe and does not interfere with, nor is affected by the operation of an MRI device